Review



multiband pass filter cube 86012v2 dapi fitc txred cy5  (Nikon)


Bioz Verified Symbol Nikon is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 99

    Structured Review

    Nikon multiband pass filter cube 86012v2 dapi fitc txred cy5
    Multiband Pass Filter Cube 86012v2 Dapi Fitc Txred Cy5, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 65417 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/Objectives/pm39976108-65-38-45
    Average 99 stars, based on 65417 article reviews
    multiband pass filter cube 86012v2 dapi fitc txred cy5 - by Bioz Stars, 2026-11
    99/100 stars

    Images

    Related Articles

    Imaging:

    Article Title: Variant-Specific Interactions at the Plasma Membrane: Heparan Sulfate's Impact on SARS-CoV-2 Binding Kinetics.
    Article Snippet: .. XXXX, XXX, XXX−XXX B were rinsed in PBS and kept in PBS at 4 °C until imaging on a Nikon Ti2-E microscope in a widefield configuration, using a Spectra III solid-state light source (555 nm emission wavelength), a multiband pass filter cube 86012v2 DAPI/ FITC/TxRed/Cy5 (Nikon Corporation, Melville, USA), a CFI Apochromat TIRF 60XC oil-immersion 60× objective (Nikon, NA: 1.49), and a Prime 95B sCMOS camera (Teledyne Photometrics, Birmingham, UK). ..

    Article Title: Efficient clathrin-mediated entry of enteric adenoviruses in human duodenal cells.
    Article Snippet: Micrographs were acquired with a Ceta 16M CCD camera (FEI, Eindhoven, The Netherlands). .. Imaging of AdV particles diffusing on live cells was performed using a Nikon Ti2-E inverted microscope equipped with a two-color laser source (wavelengths: 488 nm and 562 nm), a Prime 95B sCMOS camera (Teledyne Photometrics), and a multiband filter cube (86012v2 DAPI/FITC/TxRed/Cy5, Nikon Corp.). ..

    Article Title: Efficient clathrin-mediated entry of enteric adenoviruses in human duodenal cells
    Article Snippet: Micrographs were acquired with a Ceta 16M CCD camera (FEI, Eindhoven, The Netherlands). .. Imaging of AdV particles diffusing on live cells was performed using a Nikon Ti2-E inverted microscope equipped with a two-color laser source (wavelengths: 488 nm and 562 nm), a Prime 95B sCMOS camera (Teledyne Photometrics), and a multiband filter cube (86012v2 DAPI/FITC/TxRed/Cy5, Nikon Corp.). .. The images were collected using a 60× oil immersion objective (numerical aperture: 1.49, MRD01691, Nikon Corp.), 488 nm excitation wavelength, and HILO microscopy configuration, which allows imaging of the apical cell surface while reducing out-of-focus signal and background noise when compared to epifluorescence.

    Article Title: Variant-Specific Interactions at the Plasma Membrane: Heparan Sulfate’s Impact on SARS-CoV-2 Binding Kinetics
    Article Snippet: .. The wells were rinsed in PBS and kept in PBS at 4 °C until imaging on a Nikon Ti2-E microscope in a widefield configuration, using a Spectra III solid-state light source (555 nm emission wavelength), a multiband pass filter cube 86012v2 DAPI/FITC/TxRed/Cy5 (Nikon Corporation, Melville, USA), a CFI Apochromat TIRF 60XC oil-immersion 60× objective (Nikon, NA: 1.49), and a Prime 95B sCMOS camera (Teledyne Photometrics, Birmingham, UK). ..

    Article Title: Efficient clathrin-mediated entry of enteric adenoviruses in human duodenal cells
    Article Snippet: Micrographs were acquired with a Ceta 16M CCD camera (FEI, Eindhoven, The Netherlands). .. Imaging of AdV particles diffusing on live cells was performed using a Nikon Ti2-E inverted microscope equipped with a two-color laser source (wavelengths: 488 nm and 562 nm), a Prime 95B sCMOS camera (Teledyne Photometrics) and a multiband filter cube (86012v2 DAPI/FITC/TxRed/Cy5, Nikon Corp.). .. The images were collected using a 60x oil immersion objective (numerical aperture: 1.49, MRD01691, Nikon Corp.), 488 nm excitation wavelength and HILO microscopy configuration, which allows imaging of the apical cell surface while reducing out-of-focus signal and background noise when compared to epifluorescence.

    Microscopy:

    Article Title: Variant-Specific Interactions at the Plasma Membrane: Heparan Sulfate's Impact on SARS-CoV-2 Binding Kinetics.
    Article Snippet: .. XXXX, XXX, XXX−XXX B were rinsed in PBS and kept in PBS at 4 °C until imaging on a Nikon Ti2-E microscope in a widefield configuration, using a Spectra III solid-state light source (555 nm emission wavelength), a multiband pass filter cube 86012v2 DAPI/ FITC/TxRed/Cy5 (Nikon Corporation, Melville, USA), a CFI Apochromat TIRF 60XC oil-immersion 60× objective (Nikon, NA: 1.49), and a Prime 95B sCMOS camera (Teledyne Photometrics, Birmingham, UK). ..

    Article Title: Variant-Specific Interactions at the Plasma Membrane: Heparan Sulfate’s Impact on SARS-CoV-2 Binding Kinetics
    Article Snippet: .. The wells were rinsed in PBS and kept in PBS at 4 °C until imaging on a Nikon Ti2-E microscope in a widefield configuration, using a Spectra III solid-state light source (555 nm emission wavelength), a multiband pass filter cube 86012v2 DAPI/FITC/TxRed/Cy5 (Nikon Corporation, Melville, USA), a CFI Apochromat TIRF 60XC oil-immersion 60× objective (Nikon, NA: 1.49), and a Prime 95B sCMOS camera (Teledyne Photometrics, Birmingham, UK). ..

    Inverted Microscopy:

    Article Title: Efficient clathrin-mediated entry of enteric adenoviruses in human duodenal cells.
    Article Snippet: Micrographs were acquired with a Ceta 16M CCD camera (FEI, Eindhoven, The Netherlands). .. Imaging of AdV particles diffusing on live cells was performed using a Nikon Ti2-E inverted microscope equipped with a two-color laser source (wavelengths: 488 nm and 562 nm), a Prime 95B sCMOS camera (Teledyne Photometrics), and a multiband filter cube (86012v2 DAPI/FITC/TxRed/Cy5, Nikon Corp.). ..

    Article Title: Efficient clathrin-mediated entry of enteric adenoviruses in human duodenal cells
    Article Snippet: Micrographs were acquired with a Ceta 16M CCD camera (FEI, Eindhoven, The Netherlands). .. Imaging of AdV particles diffusing on live cells was performed using a Nikon Ti2-E inverted microscope equipped with a two-color laser source (wavelengths: 488 nm and 562 nm), a Prime 95B sCMOS camera (Teledyne Photometrics), and a multiband filter cube (86012v2 DAPI/FITC/TxRed/Cy5, Nikon Corp.). .. The images were collected using a 60× oil immersion objective (numerical aperture: 1.49, MRD01691, Nikon Corp.), 488 nm excitation wavelength, and HILO microscopy configuration, which allows imaging of the apical cell surface while reducing out-of-focus signal and background noise when compared to epifluorescence.

    Article Title: Efficient clathrin-mediated entry of enteric adenoviruses in human duodenal cells
    Article Snippet: Micrographs were acquired with a Ceta 16M CCD camera (FEI, Eindhoven, The Netherlands). .. Imaging of AdV particles diffusing on live cells was performed using a Nikon Ti2-E inverted microscope equipped with a two-color laser source (wavelengths: 488 nm and 562 nm), a Prime 95B sCMOS camera (Teledyne Photometrics) and a multiband filter cube (86012v2 DAPI/FITC/TxRed/Cy5, Nikon Corp.). .. The images were collected using a 60x oil immersion objective (numerical aperture: 1.49, MRD01691, Nikon Corp.), 488 nm excitation wavelength and HILO microscopy configuration, which allows imaging of the apical cell surface while reducing out-of-focus signal and background noise when compared to epifluorescence.

    Widefield:

    Article Title: Variant-Specific Interactions at the Plasma Membrane: Heparan Sulfate’s Impact on SARS-CoV-2 Binding Kinetics
    Article Snippet: .. The wells were rinsed in PBS and kept in PBS at 4 °C until imaging on a Nikon Ti2-E microscope in a widefield configuration, using a Spectra III solid-state light source (555 nm emission wavelength), a multiband pass filter cube 86012v2 DAPI/FITC/TxRed/Cy5 (Nikon Corporation, Melville, USA), a CFI Apochromat TIRF 60XC oil-immersion 60× objective (Nikon, NA: 1.49), and a Prime 95B sCMOS camera (Teledyne Photometrics, Birmingham, UK). ..

    other:

    Article Title: Individual-Based Approach to Modeling Hyphal Growth of a Biocontrol Fungus in Soil
    Article Snippet: At each sample time, the soil within each container was homogenized by suspending it in 200 ml of 50 mM sodium phosphate buffer, and then placing on a rotary shaker (150 rpm) for 1 h. Subsamples (1 ml) were filtered through nonfluorescent membrane filters (Millipore MF Black Filter, 0.8 μm; Millipore, Billerica, MA) and viewed at ×100 with epifluorescence to observe GFP activity, using a Nikon Eclipse E1000 Microscope (Nikon, Melville, NY) with a multiband DAPI-FITC-Rhodamine filter cube (excitation wavelengths of 380 to 400, 470 to 490, and 545 to 565 nm; dichroic mirror wavelengths of 425 to 470, 500 to 540, and 570 nm; and barrier wavelengths of 450 to 465, 510 to 540, and 580 to 620 nm).



    Similar Products

    99
    Nikon multiband pass filter cube 86012v2 dapi fitc txred cy5
    Multiband Pass Filter Cube 86012v2 Dapi Fitc Txred Cy5, supplied by Nikon, used in various techniques. Bioz Stars score: 99/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/Objectives/pm39976108-65-38-45
    Average 99 stars, based on 1 article reviews
    multiband pass filter cube 86012v2 dapi fitc txred cy5 - by Bioz Stars, 2026-11
    99/100 stars
      Buy from Supplier

    90
    Carl Zeiss multiband filter cube (dapi/fitc/texasred)
    Multiband Filter Cube (Dapi/Fitc/Texasred), supplied by Carl Zeiss, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/15+filter+set/pm39555723-251-14-3
    Average 90 stars, based on 1 article reviews
    multiband filter cube (dapi/fitc/texasred) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Nikon multiband filter cube (86012v2 dapi/fitc/txred/cy5)
    Multiband Filter Cube (86012v2 Dapi/Fitc/Txred/Cy5), supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/pm37823645-389-37-42
    Average 90 stars, based on 1 article reviews
    multiband filter cube (86012v2 dapi/fitc/txred/cy5) - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Nikon multiband filter cube (86012v2 dapi/fitc/txred/cy5
    Multiband Filter Cube (86012v2 Dapi/Fitc/Txred/Cy5, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/86012v2/pmc10617564-351-37-42
    Average 90 stars, based on 1 article reviews
    multiband filter cube (86012v2 dapi/fitc/txred/cy5 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Nikon multiband filter cube 86012v2 dapi/fitc/txred/cy5
    Multiband Filter Cube 86012v2 Dapi/Fitc/Txred/Cy5, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/bio_rxiv__2023__03__06__531250-292-37-42
    Average 90 stars, based on 1 article reviews
    multiband filter cube 86012v2 dapi/fitc/txred/cy5 - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    90
    Nikon multiband dapi-fitc-rhodamine filter cube
    Multiband Dapi Fitc Rhodamine Filter Cube, supplied by Nikon, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/multiband+filter+cube+(dapi/multiband+dapi+fitc+rhodamine+cube/10__1094_slash_phyto___96___1108-134-74-65
    Average 90 stars, based on 1 article reviews
    multiband dapi-fitc-rhodamine filter cube - by Bioz Stars, 2026-11
    90/100 stars
      Buy from Supplier

    Image Search Results